Stiffness Based Tuning

Less setup, more testing




QUICKER PROCESS


Over 75% time saving by using patented tuning technique

MORE ACCESSIBLE


Simple process builds user confidence and reduces reliance on experts.

NO PRE-CYCLING


No specimen damage before
the start of your test

IMPROVED ACCURACY


Perfectly tuned system helps to ensure reliable data and accurate peaks.



Do you find your testing machine more complicated than your test?

Stiffness Based Tuning is a revolutionary method of tuning your fatigue testing system, which improves your machine usability and helps to improve your data accuracy. The new process is simple for all users, and without pre-cycling the specimen it helps to make your data more reliable and repeatable.

To find out more, please click on the questions below or download the PDF literature!

Now available on servohydraulic systems for the first time

Following the success of Stiffness Based Tuning on ElectroPuls™ systems since their launch in 2006, it is now fully compatible with Instron Servohydraulic testing systems.

Stiffness Based Tuning is available on all Instron systems fitted with the powerful 8800MT controller. Find out if you are eligible for a free upgrade by getting in touch via the Contact Us link below!


Tuning is the vital process undertaken before a fatigue test to allow the system to properly control the machine, and for your test to run successfully. It traditionally involves loading the test specimen with a number of sudden step changes and automatically or manually iterating the control gains until the performance meets the test requirements. This process is time consuming and daunting for less experienced users.


Fatigue systems are high performance machines that can run in load or strain control at high frequencies. Unlike a traditional position controlled electromechanical system, this requires sophisticated control techniques to provide smooth and controlled motion. Ultimately, this means the system needs to be tuned before each new test so that the performance and control is optimized for that specimen material and geometry, so your data is accurate and repeatable. Failure to tune can result in system instability and unreliable data.


Stiffness Based Tuning only requires a simple ramp within the specimen’s elastic limit to measure the specimen stiffness. Using our patented algorithms, this stiffness is then used to calculate the optimum control gains in a matter of seconds. This means no lengthy tuning process, reduced complexity and no specimen damage before the test begins!

Find out here how Ghent University in Belgium benefits from this technology!